POWER SWITCH: Press this button (Fig.1) to get electric power.
TIMER: Rotate clockwise (Fig.1) to lengthen the set strap length. Counter-clockwise to shorter.
FEED BUTTON: Press this button (Fig.1) to get the length of the strap required.
RESET BUTTON: The machine “RESET” button (Fig.1) incorporates two functions. Press this button twice to get the “RE-SET” function (To put the machine in neutral Condition). By pressing on this button for about 2-3 seconds, both “MANUAL” and “RESET” functions are available.
HEATER TEMPERATURE CONTROL: Rotate the knob (Fig.2) clockwise to raise the heater blade temperature. Counter-clockwise to lower the temperature.
HEATING COOLING TIME CONTROL: Push this button (Fig.2) forward to position “2” to get longer cooling time. Pushing it backward to position “O” will give a shorter cooling time. (Position “1” is normal.)
STRAP TENSION KNOB Rotate the knob (Fig.2) clockwise to increase the tension. Counter-clockwise to decrease the tension.
STRAP WIDTH ADJUST GUIDES: Loosen the set-screw on the strap guides and then adjust strap guides according to the width of the strap used.